Reeves G2 series Operation Manual page 25

G2 series decontamination water heater
Hide thumbs Also See for G2 series:
Table of Contents

Advertisement

Operation & Maintenance w/IPB
CONTROLS, INDICATORS AND
ITEM
CONNECTIONS
1
Bypass Lever (G2-I Only)
2
Injector Assembly (G2-I Only)
3
Power Cord, GFCI
4
Injector Inlet Filter (G2-I Only)
5
Storage Area
6
Receptacle
7
Water Source Inlet w/Air Nipple
8
Hour Meter
9
Power Switch w/Indicator Light
10
Temperature Control
11
Pressure Gauge
12
Temperature Gauge
13
Operation Decal
14
Outlet, Fresh Water
15
Outlet, Fresh Water
15
Outlet, Decon Solution (G2-I Only)
16
Fuel Tank
17
Serial Number Decal
18
Fuel Filter Assembly
19
Burner Motor Assembly
Part Number: 1006375
This document contains information proprietary to DHS Systems LLC and is intended solely for use by its customers. No portion of this document may be reproduced
for release to a third party without written consent of DHS Systems LLC.
G2 Series Decontamination Water Heater
Table 1. G2 / G2-I Water Heater Functions.
On / Off Lever to toggle between Off and Run position (G2-I
Only)
Mixes and Injects Decon solution (G2-I Only)
120V / 15A
In-Line 100 Micron Filter (G2-I Only)
Decon Solution Tank Storage (G2-I Only)
110V Auxiliary Outlet
1-1/2" Female NST, Water supply inlet. Air Nipple used for
winterization of unit
Measures actual run time
On / Off Switch with Indicator Light
Temperature control for adjusting water temperature between
full cold and 110°F
0-200 PSI Color-coded Pressure Gauge
0-180°F Color-coded Temperature Gauge
Instructional decal for ease of operation
Hose connections for fresh water to shelter or sink
Hose connections for fresh water to shelter or sink
Hose connections for Decon solution to shelter (G2-I Only)
10 Gallon multi-fuel tank
Reeves assigned serial number decal
Fuel filter with water separator
¼ HP, 120V/60Hz, 1-Phase, 3450 RPM
0004-3
FUNCTION
DHS Systems LLC
0004

Advertisement

Table of Contents
loading

This manual is also suitable for:

G2sG2s-i

Table of Contents