Operation & Maintenance w/IPB
INSTALLATION OF FUEL PUMP/SOLENOID:
2. Installing the fuel pump/solenoid as follows:
a. Install fuel pump/solenoid assembly into burner motor housing.
b. Loosely thread (2) mount bolts into the fuel pump housing; do not tighten at this time.
c. Using a 7/16" open end wrench, connect and tighten the fuel nozzle tube B-nut.
d. Using a 9/16" open end wrench, connect and tighten the fuel line B-nut at the fuel pump.
e. Using a ½" open end wrench, tighten the (2) fuel pump mounting bolts.
f.
Using a 9/16" open end wrench, connect and tighten the fuel in-line at the fuel water strainer housing.
g. Connect the solenoid electrical plug.
h. Connect power cord to power supply outlet.
i.
Perform operations and leak checks.