Bvp; Bvt; Bww; Cpf - AMX Modero ViewPoint MVP-5200i Operation/Reference Manual

5.2" modero viewpoint touch panel with intercom
Hide thumbs Also See for Modero ViewPoint MVP-5200i:
Table of Contents

Advertisement

"^" Button Commands (Cont.)

^BVP

Set the network
password for the
specified address.

^BVT

Set the computer
control network
port for the
specified address.

^BWW

Set the button
word wrap
feature to those
buttons with a
defined address
range.

^CPF

Clear all page flips
from a button.

^DLD

Set the disable
cradle LED flag.
MVP-5200i 5.2" Modero® ViewPoint® Touch Panel with Intercom
Syntax:
"'^BVP-<vt addr range>,<network password>'"
Variable:
variable text address range = 1 - 4000.
network password = 1 - 50 ASCII characters.
Example:
SEND_COMMAND Panel,"'^BVP-500,PCLOCK'"
Sets the password to PCLOCK for the specific PC control button.
Syntax:
"'^BVT-<vt addr range>,<network port>'"
Variable:
variable text address range = 1 - 4000.
network port = 1 - 65535.
Example:
SEND_COMMAND Panel,"'^BVT-500,5000'"
Sets the network port to 5000.
By default, word-wrap is Off.
Syntax:
"'^BWW-<vt addr range>,<button states range>,<word wrap>'"
Variable:
variable text address range = 1 - 4000.
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons
1 = Off state and 2 = On state).
word wrap = (0=Off and 1=On). Default is Off.
Example:
SEND_COMMAND Panel,"'^BWW-500,1,1'"
Sets the word wrap on for the button's Off state.
Syntax:
"'^CPF-<vt addr range>'"
Variable:
variable text address range = 1 - 4000.
Example:
SEND_COMMAND Panel,"'^CPF-500'"
Clears all page flips from the button.
Syntax:
"'^DLD-<status>'"
Variable:
status = (0= cradle operates normally, 1= forces the cradle LEDs to always be dim).
Example:
SEND_COMMAND Panel,"'^DLD-1'"
Disables the cradle LEDs.
Programming
113

Advertisement

Table of Contents
loading

Table of Contents