Protected Setup Pages
System Setting Page Elements (Cont.)
Master Connection:
Type
Mode
System Number
Master IP/URL
Master Port Number
Username/Password
NDP Name
Refer to the Step 3: Choose a Master Connection Mode section on page 29 for more detailed information on
using the System Settings page.
56
Sets the NetLinx Master communication values:
Sets the NetLinx Master to communicate with the panel via Ethernet, USB,
Mesh, or ICSNet. This is based on the cable connection from the rear.
• Ethernet is a CAT-5 cable (10/100Base T terminated in an RJ-45 connector)
used to network computers together and is used in most LAN (local area
networks). This description is also used to refer to both wired and wireless
communication. A Wireless Ethernet connection involves indirect
communication from the panel to a Master via a wireless connection to the
network.
• A USB connection is a direct connection from the panel's mini-USB port to a
corresponding USB port on the PC (acting as a Virtual Master).
Cycles between the connection modes: URL, Listen, NDP(UDP,) URL(UDP),
and Auto.
(Ethernet Only - disabled when USB is selected)
• URL - In this mode, enter the IP/URL, Master Port Number, and username/
password (if used) on the Master. The System Number field is read-only - the
panel obtains this information from the Master.
• Listen - In this mode, add the panel address into the URL List in NetLinx
Studio and set the connection mode to Listen. This mode allows the Modero
touch panel to "listen" for the Master's communication signals. The System
Number and Master IP/URL fields are read-only.
• NDP(UDP) - In this mode, The System Number and Master IP/URL fields are
read-only.
• URL(UDP) - In this mode, The System Number and Master IP/URL fields are
read-only.
• Auto - In this mode, enter the System Number and a username/password (if
applicable). Use this mode when both the panel and the NetLinx Master are
on the same Subnet and the Master has its UDP feature enabled. The Master
IP/URL field is read-only.
Allows entry of a system number. Default value is 0 (zero).
(ETHERNET in Auto Mode Only - disabled when USB is selected)
Sets the Master IP or URL of the NetLinx Master.
(ETHERNET in URL and URL(UDP) Modes Only - disabled when USB is
selected)
Allows entry of the port number used with the NetLinx Master. Default = 1319
(ETHERNET Only - disabled when USB is selected)
If the target Master has been previously secured, enter the alpha-numeric string
(into each field) assigned to a pre-configured user profile on the Master. This
profile should have the pre-defined level of access/configuration rights.
Displays the name of the device connecting to the Master.