SERVICE MANUAL
c. Tighten the bracket securing screw.
d. Remove the test film.
11. If DS2 is already lit:
a. Insert a flat blade screwdriver in the adjustment slot.
b. Rotate the screwdriver to move the sensor bracket down until DS2 turns off.
c. Rotate the screwdriver in the opposite direction to where DS2 initially illuminates.
d. Remove the test film.
12. Insert two sheets of 7 mil film between the separator rollers.
13. Reach down from above. Rotate the upper separator roller to drive both sheets of film forward until
they are under the roller bearing.
14. DS2 should light again.
15. If DS1 does not light:
a. Loosen the two sheet sensor bracket securing screws.
b. Insert a flat blade screwdriver in the adjustment slot. Rotate the screwdriver to move the sensor
bracket enough to light DS1.
c. Tighten the bracket securing screw, and remove the two sheets of 7 mil film.
16. If DS1 is already lit:
a. Insert a flat blade screwdriver in the adjustment slot.
b. Rotate the screwdriver to move the sensor bracket until DS1 turns off.
c. Rotate the screwdriver in the opposite direction to where DS1 initially illuminates.
d. Remove the two sheets of 7 mil film.
17. Insert the 7 mil portion of the 4/11/7 mil test film between the separator rollers.
18. Reach down from above. Rotate the upper separator roller to drive the sheet of film forward until it is
under the roller bearing.
19. Verify that DS2 lights, but DS1 does not.
20. Continue to rotate the separator roller so the 11 mil portion of the test film is under the roller bearing.
21. Verify that DS2 is still lit and that DS1 remains unlit.
22. Back the test film out of the IMAGER.
3-8
Two Sheet Sensor
One Sheet Sensor
DS1
DS2
Figure 3-7.