11.7.1) Motor oil
Consulg chapter 10.2.) "Operating Media" in the Operator's Manual 914 F.
In principle motor oil is used for lubrication of components during re-assem-
bly, except where specified otherwise. Use only oils specified in the "Chart of
Lubricants" in order to avoid chemical reaction.
11.7.2) Lithium grease
Is used on all electrical connections, to avoid leaking current. After assembly
is complete, apply Lithium grease to the connection as anti-corrosive.
11.7.3) Multi-purpose grease LZ
Generally usable, neutrally coloured multi-purpose grease, water resistant
and highly adherent. Usable for temperatures from -35°C to +120°C (-31°F to
248° F). High load capacity.
11.7.4) Corrosion inhibiting oil MOBILARMA 524
Corrosion inhibiting oil, insoluble in water, hydrocarbon basis with additives.
The pour point is below -18° C ( -3° F).
11.7.5) Grease MOLYKOTE G-N
Is used on highly loaded bearing positions as initial lubrication and at press
fits for prevention of fretting corrosion. MOLYKOTE is applied to both compo-
nents mated. It is especially mentioned where to use it.
11.7.6) LOCTITE Anti-Seize 76710
High-temperature lubricating and anti-corrosion agent. LOCTITE Anti-Seize
is always applied on both components mated and warrants for maintenance-
free bearing seats due to the hermetically sealed sliding surface.
11.7.7) PU adhesive
Serves as damping medium to prevent cable breakage due to vibration. It was
used e.g. formerly on pick-up connections on the ignition housing.
11.7.8) SILASTIC
Multipurpose one component sealing compound on silicone base, e.g. SILASTIC
732.
Especially suitable for maintenance and repair. Vulcanizes at room tempera-
tures to a viscous rubber mass and is resistant against chemicals.
To be applied only on clean, dry and grease free-foundation.
Modification no.
- 0 -
WARNING: When handling chemicals, respect the generally valid safety
directives.
Reference
Main
Date
1997 02 01
914 F
Page
77