13.5.4) Servo cable, rope sheave and spring for waste gate control

1
17
1
11
16
8
6
7
02618
Page
Date
194
1998 07 01
See fig. 154

13.5.4.1) Disassembly

Remove tension spring Q by using a suitable tool and sever securing wire W.
Loosen set screw of nipple E and pull out servo cable from the cable retainer R.
Take note of the loose compression spring T 5,5/1,2/16,9. Remove this
spring and store it in a safe place.
Remove cotter pin Y and pin U from waste gate lever I.
Now the wire rope can be pulled out from the conduit.
If required take off rope sheave O after removal of the Allen screw P M5 x 20
along with spring washer and washer.

13.5.4.2) Checking of the components

Visual inspection of all components. Check servo cable for easy movement.
ATTENTION: Renew servo cable if damaged. Refer to section 12.3.6).
Check spring engagement holes { for wear.
6
11
7
14
15
Main
914 F
3
4
5
18
12
fig. 154
Reference
TM 914-08
A
2
10
9
13
Modification no.
- 1 -