4.2.4) The sprag clutch fails to decouple from the starter

4.3) Temperature – coolant

4.3.1) Exceeding of max. admissible oil temperature

Exceeding oil

temperature

4.3.2) Exceeding of maximum permissible exhaust temperature
Exceeding ex-
haust temperature
Effectivity: 912 i Series
Edition 2 / Rev. 0
Risk of fire and danger of the electric starter overheating.
• Move the throttle lever to the idle position.
• Set the EMS main switches to "OFF".
• Switch both LANE select switches to "OFF".
• A maintenance inspection should be carried out.
Reduce engine power setting to the minimum necessary and
carry out precautionary landing.
Reduce engine power setting to the minimum necessary and
carry out precautionary landing.
• Any exceeding of the max. oil temperature must be entered
by the pilot in the logbook, stating duration and extent of
over-temperature condition.
• A maintenance inspection should be carried out.
• Check the ECU error log file.
Reduce engine power setting to the minimum necessary and
carry out precautionary landing.
• Check the exhaust temperature sensors
• Oil and coolant limits must not be exceeded
• A maintenance inspection should be carried out