Rotax 914 F Maintenance Manual page 49

Hide thumbs Also See for 914 F:
Table of Contents

Advertisement

The electric system comprises the internal generator with the charging coils for the
ignition and the ignition electrics with the electronic boxes and the 4 double ignition
coils.
Internal generator: See Pic. 22.
Consisting of stator with 8 lighting coils Q and the 2 independent working ignition
charging coils W and the ten pole magneto ring E.
The magneto ring is attached on flywheel hub R with trigger cams.
The 4 trigger coils T are fitted externally on generator.
Ignition electrics : See Pic. 23.
The ignition-electrics comprise the 4 double ignition coils Q and the two electronic
modules placed above W, and is supported vibration-damped on 3 silent blocks.
2
Pic. 23
Modification no.
- 0 -
7
1
2
5
00134
1
Reference
3
4
00133
The 3-point suspension is with one each
support on crankcase, ignition housing
and intake manifold. For safety reasons,
the ignition electrics must not be exposed
to ambient temperatures higher than 80°C
(176°F).
Main
1997 02 01
914 F
Pic. 22
Date
Page
49