8) Three-Way Solenoid Valve - Rotax 914 F Maintenance Manual

Hide thumbs Also See for 914 F:
Table of Contents

Advertisement

W
W
1
Page
Date
222
1997 02 01

13.6.2.8) Three-way solenoid valve

See Pic. 189.
The threeway solenoid valve Q is installed on engine frame.
Check for physical damage
check for air passage
For removal of the air pressure hoses refer to chapter 13.1.11.
Q
Pic. 189
00060
checking the mixture enrichment (dynamical)
For that fit a T-branch into line between solenoid valve and float chamber
to facilitate the measuring by pressure gauge of the pressure rise at
exceeding the airbox pressure of 1250 hPa. The T-branch may remain but
for normal operation it has to be securely closed.
Reading of resistance between the two terminals W :
- Sever plug connection with wiring harness but re-establish straight after
completion of check and verify tight fit and engagement of catch.
- resistance at 20°C:
ATTENTION: At physical damage, mechanical defects or readings out-
side tolerance exchange the threeway solenoid valve with-
out delay.
Main
914 F
28,3 ÷ 31,1 Ω
Reference
Modification no.
- 0 -