n ATTENTION: Utilize the complete push-on length on the connection pieces.
Take care that the airbox e is fitted horizontally and torsion-free. There must
be no additional load on the carburetor fixations.
Now the tube clamps r can be tightened on the connection tube t and, if
necessary, on air intake tube y.
Fit the pressure connection tubes u (float chamber venting) on both carbu-
retors and fuel pressure regulator o with clamps i 8. See also "pressure
connection tubes", Chapter 12.1.11).
Fit the 2 fuel tubes P on fuel pressure regulator o with banjo screws p M10
and sealing rings [ 10x14 on both sides.
Tightening torque: 17 Nm (150 in.lb)
n ATTENTION: At fitting of fuel tubes support them adequately to avoid
Reconnect plug connectors to temperature sensors and throttle valve
potentiometer.
Check plug connections for security.
1