Cleaning the engine with lye or alkaline solutions is forbidden, as a matter of
principle. Use of a high pressure cleaner may cause engine failures and rust
formation.
-
When working on the electric system and on the engine, first detach the cable of the
minus-pole and then of the plus-pole of the battery! When connecting the cables,
first connect the plus- and then the minus-pole.
-
Firmly attach engine removed from aircraft on an assembly trestle.
-
Do not let the engine run in a closed room (poisoning hazard)!
-
Always observe the engine while running from a secure place.
-
When stopping the engine, switch ignition off and remove ignition key.
-
Before refuelling, always stop the engine and remove ignition key. Do not refuel in
closed rooms. Immediately clean off spilt fuel.
-
At handling of fuel be very careful - increased fire danger! Never refuel in the
vicinity of open flames or sparks able to ignite. Do not smoke when refuelling.
-
Only use oil and fuel of the specified quality and store them in approved containers
only.