11.5) Measuring tools

Vernier callipers,
dial gauge,
micrometer, internal micrometer,
feeler gauge,
spring scale up to 50 kp (500 N).
Stroboscope:
Multimeter:
Oscilloscope:
WARNING: Using these instruments, observe the manufacturer's specifications.
Modification no.
- 0 -
BOSCH 0 684 100 308 or equivalent. Supply voltage 8 - 15 V. Flash
triggering by inductive pick-up. Flashing frequency 4500 per minute
FLUKE series 70, series 80 or equivalent.
Electronic, 3 1/2 digits indication.
Current range 10 A.
Direct voltage range 200 V minimum.
Resistance range 200 Ω ÷ 2 MΩ
Accoustic continuity tester.
TEKTRONIX 2225 or equivalent
2 channels
Analogous
Sensitivity 5 mV to 5V/div
Frequency limit 50 MHz
Reference
Main