Rap 09 Operation Panel Malfunction - OKIDATA ML590 Service Manual

Dot matrix printers
Hide thumbs Also See for ML590:
Table of Contents

Advertisement

RAP 09 Operation Panel Malfunction

START
The operation panel does not function properly.
Do the operation panel LEDs light when power is applied?
Yes
Make sure the cable from CN1 of the operation panel is properly connected to
CN7 on the main control board.
Go to A
No
Check the F1 fuse on the main control board and the fuse on the power supply
board.
Are they open?
Yes
Replace the open fuse with one that has the proper rating.
Go to A
No
Replace the power supply unit.
Go to A
A
Has the problem been resolved?
Yes
End of procedure.
No
Replace the operation panel board.
Has the problem been resolved?
Yes
End of procedure.
No
Replace the main control board.
Has the problem been resolved?
Yes
End of procedure.
No
Contact Technical Support.
Service Guide ML590/ML591
Chapter 4 Failure & Repair Analysis
Page: 167

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ml591

Table of Contents