4.6.03 ALARM/LED Display Troubleshooting Tables
Reference
Failure
Number
Description
1
Space Motor
Alarm
2
Printhead
Detection Alarm
3
Printhead A/D
Alarm
4
Printhead Gap
Alarm
5
Printhead Data
Transfer Alarm
6
Printhead Type
Alarm
7
Printhead
Connection Alarm
(1)
8
Printhead
Connection Alarm
(2)
Service Guide ML590/ML591
Chapter 4 Failure & Repair Analysis
Cause
Recommended Action
Space motor IPT
Refer to RAP 02.(
does not occur in
specified time
Printhead does
Refer to RAP 03.
not home
Thermistor is
Check the printhead
open or +5 vdc
connection then replace
shorted
main control board carriage
cable printhead
Self adjustment
Check the printhead
was not
connection then replace the
successful
main control board carriage
cable printhead
Printhead parity
Replace main control board
error
carriage cable printhead
9 pin printhead is
Replace the printhead with a
connected in a
24 pin printhead
24 pin printer
Drive current is
Check the printhead
detected during
connection then replace
no overdrive
main control board carriage
signal
cable printhead
Overdrive signal
Check the printhead
is active but no
connection then replace
current is
main control board carriage
detected
cable printhead
Page: 155