water inlet bend (5):

slip-on length
◆ NOTE:
■ CAUTION:
Effectivity: 914 Series
Edition 2 / Rev. 0
BRP-Rotax
INSTALLATION MANUAL
outside dia. 27 mm (1 1/16")
max. 19 mm (3/4")
Fig. 20
00562
5
Choose between six possible fit-
ting positions of water inlet bend (5) appropriate to specific
installation (see Fig.).
The inlet bend is attached to the water pump by two Allen screws
M6x20 and lock washers. Tighten screws to 10 Nm (90 in.lb.).
Utilize total slip-on length for hose connection. Secure hoses with
suitable spring type clamp or screw clamp.