7) Electric Fuel Pumps - Rotax 914 series Installation Manual

914 series
Hide thumbs Also See for 914 series:
Table of Contents

Advertisement

19.4.7) Electric fuel pumps

11,75
8
0,46 in.
0,32 in.
Fig. 78
05120
Effectivity: 914 Series
Edition 2 / Rev. 0
INSTALLATION MANUAL
See Fig. 78/79.
-
installation:
-
voltage:
-
connections:
suitable for ring terminals to DIN 46225
For radio interference suppression a capacitor (Fig. 69 Pos. (41)) of 1µF /
100 V has to fitted as near as possible to the terminals.
▲ WARNING: The certification to the latest requirements such as FAR or
EASA has to be conducted by the aircraft manufacturer.
M5
M4
+
Anschluß
connector
-
current input:
The current input per fuel pumps
The diagram shows the current input over pressure.
Take note of the following:
-
The diagram outlines minimum capacity at nominal voltage on pump.
-
Pressure- and suction head are "ZERO".
-
Graph is effective on a seasoned pump only, running-in period
approx. 30 min.
-
Fuse:
Each of the two fuel pumps has to be protected by y slow blowing 5A fuse
in accordance with wiring diagram (Fig. 69).
BRP-Rotax
see fuel system, section 14
12 V/DC
+ terminal:
M 4 screw connection
- terminal:
M 5 screw connection
3,0 A
2,5
2,0
1,5
0
250
by one fuel pump ~ 1,7 A
by two fuel pumps (Series) ~ 1,5 A
500
750
1000
Δ p
Fig. 79
02505
1250 hPa
page 118
July 01/2008