15.2) Connections for Bowden-cable actuation and limit load.

See Fig. 55/56.
-
connection for throttle actuation (1)
connection on throttle lever:
action travel:
actuating force:
limit load:
◆ NOTE:
-
connection for starting carb (choke) actuation (2)
connection on choke lever:
action travel:
actuating force:
limit load:
Directive for choke actuation
The choke shaft (3) is marked (4). This mark has to point towards cable engagement
(5).
1
Effectivity: 914 Series
Edition 2 / Rev. 0
BRP-Rotax
INSTALLATION MANUAL
Throttle opens by spring.
2
Fig. 55
08415
set screw M 5x12
tightening torque: 4 Nm (35 in.lb)
(suitable for 1,5 mm (.06 in.) steel wire)
1
65 mm (2
/
")
2
min. 1,5 N (.3 lb)
max. 8 N (1,8 lb)
20 N (4,5 lb)
clamping nipple 6
(suitable for 1,5 mm (.06 in.) steel wire)
15
23 mm (
/
")
16
min.10 N (2,2 lb)
max. 45 N (10 lb)
100 N (22 lb)
3
4
5
05089
Fig. 56
2
2,2
0,09 in.
5,2
0,21 in.
page 93
July 01/2008