2) Rectifier-Regulator - Rotax 914 series Installation Manual

914 series
Hide thumbs Also See for 914 series:
Table of Contents

Advertisement

19.4.2) Rectifier-regulator

Description of connections:
G =
yellow - from generator
R =
red - to battery, positive terminal
+B =
battery positive terminal
L
=
warning lamp circuit
C =
control or field circuit
Effectivity: 914 Series
Edition 2 / Rev. 0
INSTALLATION MANUAL
See Fig. 71/72.
-
type: electronic full-wave rectifier regulator
-
effective voltage:
-
current limit:
-
max. permissible
component temperature: +80 °C (176 °F)
(measured in area (1))
-
weight:
◆ NOTE:
The performance specifications are given for optimal cooled
components. If necessary, use a separate heat sink for the
rectifier regulator.
BRP-Rotax
14 ± 0,3 V (from 1000 ± 250 r.p.m.)
max. 22 A
0,3 kg (.66 lb)
1
Fig. 71
09168
page 112
July 01/2008