19) Electric system

See Fig. 69.
The engine is supplied with the wiring completed and ready to operate. Only the following
connections to the aircraft have to be established.
◆ NOTE:
- integrated generator
- external rectifier-regulator
- electronic modules
- electric starter
- start relay
- 2 electric fuel pumps
- TCU
- isolating switch for servo motor
- 2 lamps (boost- and warning lamp)
- items conditional for operation like circuit breakers, ON-OFF switches, control lamps,
relays, instrumentation and capacitors
Optional extras
- external alternator (as option if the output of the integrated generator is inadequate)
- electric tachometer (accessory)
- appliance (battery) not supplied by BRP-Rotax
Effectivity: 914 Series
Edition 2 / Rev. 0
BRP-Rotax
INSTALLATION MANUAL
Throughout this documentation as name for the "electrical load pressure
control" TCU stands for Turbo Control Unit.