1) Drainage Pipelines To Airbox And Trip Tray - Rotax 914 series Installation Manual

914 series
Hide thumbs Also See for 914 series:
Table of Contents

Advertisement

15.1.1) Drainage pipelines to airbox and trip tray

Effectivity: 914 Series
Edition 2 / Rev. 0
INSTALLATION MANUAL
▲ WARNING: Connect drainage lines well, otherwise emerging fuel from a
possible leakage could drip onto the exhaust system. R I S K
OF FIRE!
-
The lines have to be routed such that in case of a damage the surplus fuel
is drained off suitably.
-
Route the lines without kinks and avoid tight bends
-
Route the lines with a continuous decline.
-
The lines have to be protected against any kind of blockage e.g. by
formation of ice.
■ CAUTION:
With closed or blocked leakage piping, fuel could end up on
exhaust system. RISK OF FIRE!
Connecting nipple (2) and (P2) for leakage line
outside dia. ø
slip on length
1
BRP-Rotax
6 mm (1/4")
max. 17 mm (11/16")
2
08415
Fig. 54
P2
page 92