Fig. 17
09152
Effectivity: 914 Series
Edition 2 / Rev. 0
INSTALLATION MANUAL
The measuring of the coolant exit temperature is performed using a separate
sensor, which has to be installed in the line between expansion tank (1) and
radiator inlet (2).
2
The sensor may be installed in a „TEE" inline with the fluid hose or the
expansion tank may be modified to attach the sensor (not supplied by BRP-
Rotax).
▲ WARNING: Do not restrict the coolant flow with the sensor devise.
■ CAUTION:
It is possible to receive a misleading reading when measuring
fluid temperatures. If fluid volume is lost and the probe is not
fully submerged in the fluid the display could show a lower
temperature than actual (measuring air temperature instead
of fluid temperature).
BRP-Rotax
1
page 47
July 01/2008