19.4.10)Boost lamp

19.4.11)Caution lamp

Effectivity: 914 Series
Edition 2 / Rev. 0
INSTALLATION MANUAL
See Fig. 69.
-
colour of lamp:
-
voltage:
-
current:
-
connections:
+ terminal: flexible wire 0,75 mm
- terminal: flexible wire 0,75 mm
* from the 36 pole plug receptacle of the TCU, plug 6,3 x 0,8 to DIN 46247
-
length approx. 600 mm (24 in) from TCU
■ CAUTION:
Do not connect the - (neg.) terminal to ground or the + (pos.)
terminal to bus (12 volt), each wire must be connected directly
to the lamp. Use a two wire lamp; do not use a lamp that
grounds through the base as this will defeat the warning
system.
See Fig. 69.
-
Colour of lamp:
-
Voltage:
-
current:
-
connections:
* from the 36 pole plug receptacle of the TCU, plug 6,3 x 0,8 to DIN 46247
-
length approx. 600 mm (24 in) from TCU
■ CAUTION:
Do not connect the - (neg.) terminal to ground or the + (pos.)
terminal to bus (12 volt), each wire must be connected directly
to the lamp. Use a two wire lamp; do not use a lamp that
grounds through the base as this will defeat the warning
system.
BRP-Rotax
red or colour as per effective regulations.
12 V(DC)
depending on input voltage of TCU.
max. 0,5 A
orange or colour as per effective regulations.
12 V(DC)
depending on input voltage of the TCU
max. 0,5 A
+ terminal: flexible wire 0,75 mm
- terminal:flexible wire 0,75 mm
2
(18 AWG) white No. 10*
2
(18 AWG) white No. 28*
2
(18 AWG) white No. 35*
2
(18 AWG) white No. 11*