13.12)Replacement of components

If a malfunction of hydraulic valve tappet should be found during this check of priming
process, the relevant hydraulic valve tappet has to be replaced and the valve spring
support has to be inspected for wear.
All work has to be performed in accordance with the relevant Maintenance Manual.
pressure.....max. 1 bar
(15 psi)
max. 0,5 mm
(0,02 in.)
Effectivity: 914 Series
Edition 2 / Rev. 0
INSTALLATION MANUAL
appropriate plug
6
F
05446
Fig. 46
BRP-Rotax
5
08413
Fig. 45
7
1
3
direction of rotation of engine
2
4
to oil pump (1)
back from
engine (2)
05448