Removal Of The Blinding Shim; Removal Of The Oil Inlet Flange - Rotax 915 i A Series Maintenance Manual

Hide thumbs Also See for 915 i A Series:
Table of Contents

Advertisement

REMOVAL OF THE BLINDING SHIM

CONFIGURATION 2
Step
Procedure
1
Loosen the countersunk screw M5x12 in-
clude the trust washer for the blinding
shim fastening.
2
Press the blinding shim out towards the
gearbox with a suitable insertion jig.
Figure 6.17
Countersunk screw
1
M5x12
Blinding shim
3
Figure 6.18
Insertion jig part no.
1
276332
72–10–00
Page 14
June 01 2019
BRP-Rotax
MAINTENANCE MANUAL HEAVY
2
Thrust washer
Blinding shim
2

REMOVAL OF THE OIL INLET FLANGE

CONFIGURATION 2
Step
Procedure
1
Loosen 2 Allen screws M6x16 for the oil
inlet flange fastening.
2
Remove the oil inlet flange with the two
O-rings behind it.
Figure 6.19
1
Allen screws M6x16
Oil inlet flange
3
2
O-rings
Effectivity: 915 i A Series