17.1) Static pressure sensor
See Fig. 65.
-
effective range:
deviation:
-
operating temperature: min.
-
dimensions and attachment:
-
fitting position:
The pressure connection (Pos. (3) Fig. 65) points downwards to prevent possible
condensate from entering the sensor, i.e. the longitudinal axis z4 has to be parallel
to z-axis in system of coordinates.
tolerated deviation of parallelism: ± 60°
-
location of installation:
vibration neutralized installation in a stable zone, e.g. in cockpit.
In the area of the pressure pick-up approx. the same atmospheric pressure (static
air pressure) has to prevail as at inlet of turbo charger.
■ CAUTION:
■ CAUTION:
◆ NOTE:
-
length of cable assy.:
Effectivity: 914 Series
Edition 2 / Rev. 0
BRP-Rotax
INSTALLATION MANUAL
100 - 1200 hPa
max. ± 40 hPa
- 40 °C (-40 °F)
max. +125 °C (257 °F)
see sketch (Fig. 65)
Remove protective cap before operating the sensor.
The pressure connection has to be protected against entering of
foreign matter e.g. oil, fuel, water etc.
Location of installation is limited by the length of the wiring harness.
approx. 250 mm (10 in.) from TCU.
+z4
ø3
ø0,12 in.
ø4,7
ø0,19 in.
60°
-z4
24
0,95 in.
21
0,83 in.
3
60°
Fig. 65
05091
page 104
July 01/2008