12.6) Requirements on the cooling system

■ CAUTION:
▲ WARNING: The size and layout of the cooling system must be designed to keep
Coolant hoses:
-
temperature durability:
-
pressure durability:
-
nom. inside dia :
-
bending radius:
-
material:
■ CAUTION:
◆ NOTE:
Effectivity: 914 Series
Edition 2 / Rev. 0
BRP-Rotax
INSTALLATION MANUAL
All components of the cooling system have to be secured suitably.
the heat of the operating temperatures within the specified limits.
To minimize flow resistance employ a radiator with low flow
resistance and parallel flow as realized on the original BRP-Rotax
radiator and use short hoses and pipelines.
min. 125 °C (257 °F)
min. 5 bar (73 p.s.i.)
25 mm (1")
min. 175 mm (7")
Suitable for 100 % Glycol and antifreeze agents.
All hoses which are exposed to the radiated heat from the exhaust
system have to be shielded in an appropriate way (i.e.: with a heat
resistant hose).
Instead of long hoses, aluminium pipes may be used (inner
diameter 25 mm (1")). These should come with a bead (1) to avoid
loose coolant hoses.
1
09158
Fig. 18
July 01/2008
page 50