Error Messages; Post Error Messages - Fujitsu PRIMERGY BX620 S4 User Manual

Hide thumbs Also See for PRIMERGY BX620 S4:
Table of Contents

Advertisement

Chapter 9 Operation and Maintenance

9.2.2 Error Messages

This section explains the error messages for this server.

POST error messages

If an error occurs during Power On Self Test, a device check performed during the server startup,
(POST), deal with it according to the following table.
When checking/changing the settings of the BIOS Setup Utility, refer to "8.2 BIOS Setup Utility"
( pg.205).
For instructions on checking peripheral connections, refer to the "Start Guide".
For details on installing internal options, refer to "Chapter 7 Installing Internal Options" ( pg.171).
Message
Boot Failure
Invalid Boot Diskette
Reboot and Select proper Boot device or Insert Boot
Media in selected Boot device and press a key
Interrupt Controller-1 error
Interrupt Controller-2 error
CMOS Battery Low
CMOS Checksum Bad
CMOS Date/Time Not Set
234
table: List of POST Error Messages
OS booting has failed.
Check to see whether the drives (hard disk, CD/DVD drive,
floppy disk drive, etc.) and cables to be used for booting have no
error. If the message still appears, the Server Blade must be
replaced. Contact an office listed in the "Contact Information"
of the "Start Guide".
Booting disk error has occurred.
Check to see whether the drives (hard disk, CD/DVD drive,
floppy disk drive, etc.) and cables to be used for booting have no
error. If the message still appears, the Server Blade must be
replaced. Contact an office listed in the "Contact Information"
of the "Start Guide".
No drive to boot OS is detected.
Check to see whether the drives (hard disk, CD/DVD drive,
floppy disk drive, etc.) and cables to be used for booting have no
error. If the message still appears, the Server Blade must be
replaced. Contact an office listed in the "Contact Information"
of the "Start Guide".
An interrupt controller error has occurred.
The Server Blade must be replaced. Contact an office listed in
the "Contact Information" of the "Start Guide".
CMOS battery (button battery) is close to burned out. Contact
an office listed in the "Contact Information" of the "Start
Guide".
A CMOS setting or checksum error has occurred.
Correct the current settings using the BIOS Setup Utility or
restore the default settings.
If the message still appears, the Server Blade must be replaced.
Contact an office listed in the "Contact Information" of the
"Start Guide".
The time and date may not be set. Enter the correct time and
date on "8.2.2 Main Menu" ( pg.208) of the BIOS Setup
Utility.
Contents and troubleshooting

Advertisement

Table of Contents
loading

Table of Contents