Event logs

When AFT, ALB, or SFT is used, the following event logs will be generated (source: i ANSMiniport).
ID
Type
6
Information
The primary adapter has been initialized: (Adapter name)
7
Information
The adapter has been initialized: (Adapter name)
8
Information
(Team name): The team has been initialized.
10
Information
The current primary adapter is changed from the next adapter: (Adapter name)
11
Warning
The next adapter link is not connected: (Adapter name)
12
Information
The secondary adapter has a priority: (Adapter name)
13
Warning
(Adapter name) has been disabled with a team.
14
Information
The secondary adapter has been added to a team again: (Adapter name)
15
Information
The next adapter link is connected: (Adapter name)
16
Error
(Team name): The last adapter has been unlinked. Network connection has failed.
17
Information
(Team name): The adapter has established a link again. The network connection has been
18
Information
The primary adapter at the next priority level has been detected: (Adapter name)
19
Information
The secondary adapter at the next priority level has been detected: (Adapter name)
20
Information
The primary adapter at the next priority level is preferentially handled: (Adapter name)
21
Information
The secondary adapter at the next priority level is preferentially handled: (Adapter name)
22
Warning
The primary adapter could not detect the next probe: (Adapter name) Cause: The team
may be divided into groups.
35
Warning
(Team name) without one adapter is initialized. Confirm that all adapters exist and
function.
38
Information
(Adapter name) has been deleted from the team.
42
Warning
(Adapter name) is not specified properly. The adapter cannot process the remote
management function while being a network team.
Notes
• When the teaming function normally starts running, event logs (ID = 6 to 8) are stored at boot of the
system. This is not a problem; no action is required.
• Once a Team is setup, plural warning logs (ID = 11) and event logs (ID =15, etc.) may be stored in
the system log of the event viewer at boot of the system. This is not a problem; no action is required.
PRIMERGY BX620 S4 Server Blade User's Guide
table: Event log messages
Message
recovered.