SERVICE PROGRAM MODE TABLES

8. SERVICE PROGRAM MODE TABLES
NOTE: Items marked with
8.1 MAIN SP MODE TABLE
NOTE: 1. In the Function column, comments are in italics.
2. In the Settings column, the default value is in bold letters.
3. An asterisk " * " after the mode number means that this mode is
stored in the NVRAM. If you do a RAM reset, all these SP modes
will be reset to their factory settings.
Mode No.
Class 1 Class 2
Leading Edge
Registration
1001 *
Side-to-Side
Registration
(Duplex)
1 *
Side-to-Side
Registration
(1st paper
2 *
feed)
1002 *
Side-to-Side
Registration
(2nd paper
3 *
feed: Option
PFU tray 1)
Side-to-Side
Registration
(3rd paper
4 *
feed: Option
PFU tray 2)
are new or modified items.
Function
Adjusts the printing leading edge
registration using Trimming Area Pattern
(SP2902-3, No.10).
Use the •/∗ key to toggle between + and -.
The specification is 3 ± 2 mm. See
"Replacement and Adjustment - Copy
Image Adjustments"in the AD3 service
manual for details.
Adjusts the printing side-to-side
registration from the duplex tray using the
Trimming Area Pattern (SP2902-3, No.10).
Use the •/∗ key to toggle between + and -.
The specification is 2 ± 1.5 mm. See
"Replacement and Adjustment - Copy
Image Adjustments"in the AD3 service
manual for details on SP1002
Adjusts the printing side-to-side
registration from the 1st paper feed
station using the Trimming Area Pattern
(SP2902-3, No.10).
Use the •/∗ key to toggle between + and -.
The specification is 2 ± 1.5 mm.
Adjusts the printing side-to-side
registration from the 2nd paper feed
station using the Trimming Area Pattern
(SP2902-3, No.10).
Use the •/∗ key to toggle between + and -.
The specification is 2 ± 1.5 mm.
Adjusts the printing side-to-side
registration from the 3rd paper feed
station using the Trimming Area Pattern
(SP2902-3, No.10).
Use the •/∗ key to toggle between + and -.
The specification is 2 ± 1.5 mm.
14
25 April 1997
Settings
+9 ~ -9
0.1 mm/step
+ 0.0 mm
+9 ~ -9
0.1 mm/step
+ 0.0 mm
+9 ~ -9
0.1 mm/step
+ 0.0 mm
+9 ~ -9
0.1 mm/step
+ 0.0 mm
+9 ~ -9
0.1 mm/step
+ 0.0 mm