Kyocera TASKalfa 220 Service Manual page 71

Hide thumbs Also See for TASKalfa 220:
Table of Contents

Advertisement

Maintenance
item No.
Method to set or check the original size detection threshold
U099
1. Place an original on the contact glass and turn the original detection switch on. The original size detec-
(cont.)
tion starts and detection data is displayed.
2. Change the detection item using the exposure adjustment keys.
Exposure
indicator
Exp. 1
Exp. 2
Exp. 3
Exp. 4
Exp. 5
3. To change the original size detection threshold, light exp. 1, 2 or 3 and change the setting using the
zoom +/- keys.
4. Press the start key. The value is set.
5. Press the stop/clear key. The selected item appears.
Completion
Press the stop/clear key. The screen for selecting a maintenance item No. is displayed.
Description
Description
Detection sensor threshold value
Original size judgment time
Threshold value in the main scan direction for
A4R detection
Original size detection position display (mm)
Detected original size display
Setting
Initial
range
setting
0 to 255
170
0 to 100 ms
30
220/240 mm
240
0 to 350 mm
-
0 to 63*
-
2KL/2KK
1-3-33