1-5-3

Optical section

(1) Detaching and refitting the exposure lamp

Follow the procedure below to replace the exposure lamp.
Procedure
1. Remove the original cover or the document
processor.
2. Remove two screws and remove the right
upper cover.
Remove the contact glass.
3. Open the front cover and left cover.
4. Remove the front left cover (see page 1-5-
40 ).
5. Release five hooks and both and then
remove the front scanner cover.
6. Remove two screws and remove the rear
upper cover.
Screw
Contact glass
Figure 1-5-27
Rear upper cover
Front scanner cover
Front scanner cover
Hook
Hook
Hook
Both
Figure 1-5-28
Screw
Right upper cover
Screw
Screw
Hook
Hook
2KL/2KK
1-5-17