Connector
Pin No.
YC14
1
Connected
2
to the eject
3
switch and
4
feedshift
switch
YC15
1
Connected
2
to the scan-
3
ner motor
4
YC16
1
Connected
2
to the
3
inverter
4
PWB
5
6
YC17
1
Connected
2
to the power
3
source
4
PWB, left
cover safety
5
switch and
6
front cover
7
safety
switch
8
YC18
1
Connected
2
to the power
3
source PWB
4
5
6
7
YC25
1
Connected
2
to the paper
feeder
Signal
I/O
PGND
-
EXTSWN
O
SEPSWN
O
+5V4
O
ISMDA
O
ISMDB
O
ISMDNA
O
ISMDNB
O
+24V1
O
+24V1
O
NC
-
LAMPN
O
PGND
-
PGND
-
+24V
I
+24V
I
+24V1
O
PGND
-
+24VIL1
I
+24VIL1
O
PGND
-
+24VIL2
I
MHREM
O
SLEEP
O
SHREM
O
SGND
-
RELAYREM
O
ZCROSS
I
+24V2
I
PGND
-
+24V1
O
Voltage
-
Ground
0/3.3 V DC
ESW: On/Off
0/3.3 V DC
FSSW: On/Off
5 V DC
5 V DC power output to ESW/FSSW
0/24 V DC (pulse) SM drive control signal
0/24 V DC (pulse) SM drive control signal
0/24 V DC (pulse) SM drive control signal
0/24 V DC (pulse) SM drive control signal
24 V DC
24 V DC power output to INPWB
24 V DC
24 V DC power output to INPWB
-
Not used
0/24 V DC
EL: On/Off
-
Ground
-
Ground
24 V DC
24 V DC power input from PSPWB
24 V DC
24 V DC power input from PSPWB
24 V DC
24 V DC power output to LCSSW
-
Ground
24 V DC
24 V DC power input from LCSSW
24 V DC
24 V DC power output to FCSSW
-
Ground
24 V DC
24 V DC power input from FCSSW
0/3.3 V DC
FH-M: On/Off
0/3.3 V DC
Sleep signal: On/Off
0/3.3 V DC
FH-S: On/Off
-
Ground
0/3.3 V DC
Relay signal
0/3.3 V DC (pulse) Zero-cross signal
24 V DC
24 V DC power input from PSPWB
-
Ground
24 V DC
24 V DC power output to paper feeder