Setting The Fuser Control Temperature; Stabilizing Fuser Forcibly - Kyocera TASKalfa 220 Service Manual

Hide thumbs Also See for TASKalfa 220:
Table of Contents

Advertisement

Maintenance
item No.

Setting the fuser control temperature

U161
Description
Changes the fuser control temperature.
Purpose
Normally no change is necessary. However, can be used to prevent curling or creasing of paper, or solve a
fuser problem on thick paper.
Setting
1. Press the start key.
1. Select the item to be set using the exposure adjustment keys.
2. Change the setting using the zoom +/- keys.
Exposure
indicator
Exp. 1 (lit)
Exp. 2 (lit)
Exp. 3 (lit)
Exp. 4 (lit)
Exp. 5 (lit)
Exp. 1 (flashing)
Copying operation temperature 1: Temperature in copying operation at the start of copying
Copying operation temperature 2: Temperature in copying operation after the specified number of
sheets for fuser control have passed
Number of sheets for fuser control: The number of sheets to be counted for switching from copying oper-
ation temperature 1 to copying operation temperature 2
The temperatures are to be set such that Secondary stabilization >
3. Press the start key. The value is set.
Completion
Press the stop/clear key. The screen for selecting a maintenance item No. is displayed.

Stabilizing fuser forcibly

U162
Description
Stops the stabilization fuser drive forcibly, regardless of fuser temperature.
Purpose
To forcibly stabilize the machine before the fuser section reaches stabilization temperature.
Method
1. Press the start key. "on" appears.
2. Press the start key. The forced stabilization mode is entered, and stabilization operation stops regard-
less of fuser temperature. The screen for selecting a maintenance item No. is Displayed.To exit the
forced stabilization mode, turn the power off and on.
Completion
Press the stop/clear key. The screen for selecting a maintenance item No. is displayed.
Description
Description
Primary stabilization fuser temperature
Secondary stabilization fuser temperature
Copying operation temperature 1
Copying operation temperature 2
Number of sheets for fuser control
Number of sheets for fuser control (thick paper)
Setting range
°
120 to 185 (
C)
°
120 to 185 (
C)
°
160 to 220 (
C)
°
160 to 220 (
C)
1 to 99
1 to 99
Primary stabilization.
=
2KL/2KK
Initial
setting
145
165
175
185
1
2
1-3-39