If the error message displays the location number, see Figure 4–2 for DSIMM location
numbers. If the error message displays a physical memory address, consult Table 4–4
to see which memory slot contains the physical address.
For example, if an error is detected at physical memory address 12fe958, examining
Table 4–4 shows that the error occurred in the DSIMM in slot 0.
After you have identified the defective DSIMM, follow the instructions in "Removing
a DSIMM" on page 113, for removing the defective DSIMM. To replace the DSIMM,
follow the directions in "Replacing a DSIMM" on page 115.
Figure 4–2
TABLE 4–4
Slot
0
1
2
3
4
5
1
1. Each memory slot can contain one DSIMM up to 32 megabytes in size. Slot 0 must have a DSIMM present.
SPARCstation 5 Service Manual ♦ Revision A, August 1994
34
DSIMM Slot Locations
Physical Memory Address Ranges for Slots
SIMM #
Physical Memory Address Ranges
J0300
0000 0000 through 01FF FFFF
J0301
0200 0000 through 03FF FFFF
J0302
0400 0000 through 05FF FFFF
J0303
0600 0000 through 07FF FFFF
J0400
0800 0000 through 09FF FFFF
J0401
0A00 0000 through 0BFF FFFF
1
0 Through 7