Chapter 5
PBX Flash (Centrex Flash)
MBC - 3-04
When a Hook-switch Flash is invoked by a user on a CO Line marked as CO Line
Type PBX. The hook switch flash duration ranges from 0.1 - 3.0 seconds (100ms -
3000ms).
Press chg to select.
CO Flash (Flash)
MBC - 3-05
This timer is used when an extension drops an outside CO Line call allowing it to dial
out on another CO Line or dial an internal extension or feature. The CO Flash timer
ranges from 0.1 - 3.0 seconds (100ms - 3000ms).
Press chg to select.
Remind Time (System Hold Recall)
MBC - 3-06
When a call is placed on hold, a reminder tone will be heard at the originating
extension each time this timer expires Note: Setting this parameter to zero will disable
the feature
Press chg to select.
Pause Time (Speed Dial Pause)
MBC - 3-07
The Pause time is used with special dialing features such as ABBR (Speed Dial) bins.
To input a Pause in a dial string enter Feature 70.
Press chg to select.
PBX Code
MBC - 3-08
Select between a single or double digit entry to access a PBX / CO Group.
Press chg to select.
Data Range: 0.1 - 3.0 Seconds
Factory Setting: 0.3
Data Range: 0.1 - 3.0 Seconds
Factory Setting: 0.7
Data Range: 0 - 90 Seconds
Factory Setting: 60
Data Range: 0 - 90 Seconds
Factory Setting: 1.5 Seconds
Data Range: 0 - 99
Factory Setting: 9