Table 32: Output Function Types - Bosch DS7200V2-UK Installer's Manual

Table of Contents

Advertisement

Function, Output ##
• Address: See Table 31
• Default:
− PO 1: 1|10: Alarm –Controlled zones, 24-hr zones (Fire and Non-Fire)
− PO 2: 8|8: Enhanced Siren
− PO 3: 1|6: Strobe
− PO 4: 8|5: Unconfirmed Alarm
− PO 5: 8|4: Confirmed Alarm
− PO 6: 8|7: Bypass
− PO 7: 8|9: Alarm Cancel
− PO 8: 8|10: RF Transmitter Missing
− PO 9: 8|11: RF Transmitter Low Battery
− PO 10: 8|12: RF Receiver Jamming
• Selections: 0|0 to 8|15 (see Table 32 )
This parameter assigns each output to a specific function. The function determines when the output activates. The Mode, Time
and Multiplier parameters, in combination with this Function parameter, determine when the output deactivates.
All output functions can be reset using [#][5][4] except Alarm Outputs that follow Function Types 1|8 to 1|12 and 2|11, and
those functions that can be reset by pressing [System Reset].
Digit
Digit
Function Type
1
2
0
0
Disabled
0
1
Armed – All, Perimeter
Only, or Partial On
0
2
Armed – Perimeter Only
or Partial On
0
3
Armed – All
0
4
Auto Arm Pre-Arming
Alert
0
5
Exit Delay or Entry
Delay.
0
6
Exit Delay
0
7
Exit Delay Finished (until
disarmed)
0
8
Bell Test on Close
0
9
Entry Delay
0
10
Entry Delay + Chime
0
11
Exit Delay, Entry Delay,
Chime
0
12
Phone Line Fail
0
13
Ack Received (any
report)
0
14
AC Fail
0
15
Low or Missing Battery
Page 88
P/N: 4998152533-02
PART IV: CONTROL PANEL PROGRAMMING
Output activates when the system is armed All On, Perimeter Only, or Partial On. For Steady or Pulse
modes, the output remains activated until the system is turned off.
Output activates when the system is armed Perimeter Only, or Partial On. For Steady or Pulse modes,
the output remains activated until the system is turned off, or moved to another armed state.
Output activates when the system is turned All On. For Steady or Pulse modes, the output remains
activated until the system is turned off, or moved to another armed state.
Output activates at the start of the Auto Arm Alert. For Steady or Pulse modes, the output remains
activated for the duration of the alert. See Auto On Alert Time on page 50.
Output activates at the start of Exit Delay or Entry Delay. For Steady or Pulse modes, the output
remains activated until entry or exit delay ends.
Output activates at the start of Exit Delay. For Steady or Pulse modes, the output remains activated
until exit delay ends.
Output activates at the end of Exit Delay. For Steady or Pulse modes, the output remains activated
until the system is disarmed.
For systems programmed for closing reports, the output activates when the acknowledgement for the
closing report is received. For systems not sending closing reports, the output activates at the end of
Exit Delay. For Steady or Pulse modes, the output remains activated until the system is disarmed.
Output activates at the start of Entry Delay. For Steady or Pulse modes the output remains activated
until Entry Delay ends.
Output activates at the start of Entry Delay. For Steady or Pulse modes, the output remains activated
until entry delay ends. The output also activates whenever a Chime zone is faulted. The output does
not activate if Chime Tone is turned off.
Output activates at the start of Exit Delay or Entry Delay. For Steady or Pulse modes, the output
remains activated until Entry or Exit Delay ends. The output also activates whenever a Chime zone is
faulted. The output does not activate if Chime Tone is turned off.
Output activates when a Phone Line Fail condition is detected. For Steady or Pulse modes, the output
remains activated until the condition is cleared. This output works independently of Phone Line
Fault Response Options (see the DS7200V2 Expert Programming Guide (P/N: 4998153891)).
Output activates when the acknowledgement for any report is received. For Steady or Pulse modes,
[System Reset] resets. This output type is event-driven. See Mode (Steady, Pulse, One Shot), Output
## on page 92 for more information.
Output activates when a AC Fail condition is detected. For Steady or Pulse modes, the output remains
activated until the condition is cleared.
Output activates when a panel Low or Missing Battery condition occurs. For Steady or Pulse modes,
the output remains activated until the condition is cleared.

Table 32: Output Function Types