Removal Of The Compressor - Daikin E Series Service Manual

Inverter pair wall mounted type e-series
Hide thumbs Also See for E Series:
Table of Contents

Advertisement

SiBE04-624

2.14 Removal of the Compressor

Procedure
Step
1. Remove the peripheral
parts
Remove the terminal
1
cover.
2
Detach the lead wire
for compressor.
3
Remove the protecting
bushing for the lead
wire.
Loosen the 1 fixing nut
4
for compressor.
Removal Procedure
Warning Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
Outdoor Unit
Points
Preparation
Remove the sound blanket
according to "Removal of
Sound Blanket".
Be careful so as not to burn
the compressor terminals or
the name plate.
Make a note.
V (yellow)
U (red)
W (blue)
(R6031)