SiBE04-624

1.10 Removal of the Drain Hose

Procedure
Step
1. Remove the drain hose
1
Loosen the screws of
the main unit and
installation plate.
2
Lift the main unit
slightly and remove the
drain hose. (In case of
piping on the right)
2. How to conduct piping on
the left
Detach the drain plug
1
on the left.
Removal Procedure
Warning Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
Indoor Unit
Points
Cover the drain hose with
plastic bags or the like so as
the remaining drain will not
wet the floor.
Part A is fixed by the screw
from back side. When
replacing the hose, make
sure to tighten a screw as
there is no gap between the
heat insulator and the hose.