Removal Of The Pcb - Daikin E Series Service Manual

Inverter pair wall mounted type e-series
Hide thumbs Also See for E Series:
Table of Contents

Advertisement

Outdoor Unit
2.8

Removal of the PCB

Procedure
Step
1
Loosen the 7 screws
for the PCB or the
radiation fin.
2
Remove the PCB and
the radiation fin.
284
Warning Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
SiBE04-624
Points
Preparation
Remove the electrical box
according to "Removal of
Electrical Box".
The control PCB is in up
side down.
PbF (Pb free brazing) is
adopted.
When replacing, use a
exclusive solder and
soldering iron.
In working, be careful not to
break the PCB with the
excessive force because
the PCB and the radiation
fin are adhered to one
another
When assembling, make
sure to use the silicon
material.
Silicon material
Part No.: 1172698
Removal Procedure

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading