Removal Of The Assembly Of The Reduction Motor - Daikin E Series Service Manual

Inverter pair wall mounted type e-series
Hide thumbs Also See for E Series:
Table of Contents

Advertisement

Indoor Unit
1.5

Removal of the Assembly of the Reduction Motor

Procedure
Step
1. Remove the assembly of
the reduction motor
Disconnect the
1
connector for reduction
motor [S51].
2
Loosen the 1 screw of
the assembly of the
reduction motor.
2. Remove the reduction
motor
Loosen the 1 screw.
1
230
Warning Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
SiBE04-624
Points
The figure above shows the
hook on the connector for
the assembly of reduction
motor.
When touching the electrical
parts like the limit switch, be
sure to conduct the work
after discharging static
electricity of the human
body. It may cause trouble
of the PCB.
Removal Procedure

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents