Removal Of The Connecting Duct - Daikin E Series Service Manual

Inverter pair wall mounted type e-series
Hide thumbs Also See for E Series:
Table of Contents

Advertisement

SiBE04-624
1.9

Removal of the Connecting Duct

Procedure
Step
1. Remove the connecting
duct for humidifying hose
Detach the humidifying
1
hose from the duct unit.
Loosen the 1 fixing
2
screw for the duct unit.
Lift the right side to
3
undo the projections
and slide to the left.
Removal Procedure
Warning Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
Indoor Unit
Points
Preparation
Remove the front grille
according to "Removal of
the Front Grille".
Since inside of the
connecting duct has
projection hooks, shake the
hose up and down to
remove.
Rotate in the same direction
as when assembling for
easy removal.
Put the drain hose at the
bottom and make an
inclination downward.