6. Removal of Compressor

Procedure
Step
1. Remove the peripheries.
1
Remove the terminal
cover.
2
Remove the protection
bushing.
Disconnect the
3
terminals and overload
protector.
Removal Procedure
Warning Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Procedure
Terminal cover
Protection bushing
Removal of Compressor
Points
(R14904)
(R14905)
W
(blue)
U
V (yellow)
(red)
(R14906)
19