To Set The Clock - Daikin E Series Service Manual

Inverter pair wall mounted type e-series
Hide thumbs Also See for E Series:
Table of Contents

Advertisement

SiBE04-624

To set the clock

* Time cannot be set during unit operation.
1. Press "
".
Do not hold the button.
2. Press "
3. Press "
".
Setting is complete.
ATTENTION
If other messages than time appear on the display with the step 1 operation, do not operate the button for about 60 seconds. The display will
return to normal.
Tips for saving energy
Be careful not to cool (heat) the room too much.
Keeping the temperature setting at a moderate level helps save energy.
Cover windows with a blind or a curtain.
Blocking sunlight and air from outdoors increases the cooling (heating) effect.
Clogged air filters cause inefficient operation and waste energy. Periodically clean the filter.
Please note
The air conditioner consumes power even when it is not operating.
If you are not going to use the air conditioner for a long period, for example in spring or autumn, turn the breaker OFF.
When the outdoor temperature is below –15°C, turn on the breaker more than 1 hour before starting the operation.
(This is to warm up the compressor.)
Operating conditions
Running the unit under conditions not listed below may cause the safety device to activate, stopping the unit. Also, condensation may form
on the indoor unit and drip. (DRY / COOLING operation)
Outdoor temperature : 21 to 43°C
COOLING
Indoor temperature : 18 to 32°C
Indoor humidity : 80% max.
Outdoor temperature : 10 to 42°C
DRY
Indoor temperature : 18 to 30°C
Indoor humidity : 80% max.
Reachable Humidity
The ability of humidification drops when the outdoor tem-
perature and humidity are low.
(See Fig.1 as reference.)
System Configuration
is displayed.
blinks.
" to set the clock to the present time.
• Holding the button changes the time faster.
blinks.
is displayed.
1, 3
Outdoor temperature : –20 to 24°C
HEATING
Indoor temperature : 10 to 30°C
Indoor humidity : 70% max.
Outdoor temperature : –10 to 24°C
HUMIDIFYING
Indoor temperature : 12 to 30°C
Indoor humidity : 70% max.
Fig.1 Reachable Humidity
100
80
60%
40%
60
20%
40
20
0
–10
0
10
20
Outdoor temperature (°C)
Instruction
2
Recommended temperature setting
For cooling : 26°C – 28°C
For heating : 20°C – 22°C
Condition;
Model: FTXR50EV1B
Indoor temperature setting: 20°C
Airflow rate: Max.
3
Room volume: 120m
Air change rate: 0.5/hour
Humidifying hose length: 7.5m
6
111

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents