Daikin E Series Service Manual page 266

Inverter pair wall mounted type e-series
Hide thumbs Also See for E Series:
Table of Contents

Advertisement

SiBE04-624
Step
3
Remove the fan motor
and fan rotor.
3. Remove the fan motor
1
Loosen the fixing screw
for fan rotor and fan
motor.
Remove the fan motor
2
and fan rotor.
4. Remove the bearing
1
Remove the fan rotor.
Undo the 1 hook of the
2
bearing.
Removal Procedure
Procedure
Indoor Unit
Points
The fan motor fixture (lower)
can be removed by pushing
the hook.
255