Daikin E Series Service Manual page 294

Inverter pair wall mounted type e-series
Hide thumbs Also See for E Series:
Table of Contents

Advertisement

SiBE04-624
Step
4
Disconnect the
connectors black
(power supply), white
(power supply), and
red (signal) and detach
the earth wire.
5
Undo the clip for the
thermistor assembly
fixed to the electrical
box.
6
Loosen the each 1
screw in front and on
the right of the
electrical box.
7
Lift the electrical box to
remove.
Removal Procedure
Procedure
Outdoor Unit
Points
Black-power supply
White-power supply
Red-signal
Green/Yellow-earth
The clip is push-mount type.