Daikin E Series Service Manual page 263

Inverter pair wall mounted type e-series
Hide thumbs Also See for E Series:
Table of Contents

Advertisement

Indoor Unit
Step
2. Remove the indoor unit
Remove the indoor unit
1
from the installation
plate.
3. Remove the heat
exchanger
Unfasten the hook of
1
the pipe fixing plate at
the back of the unit and
pull out the pipe.
Widen the auxiliary
2
pipe by about 10-20
degrees.
252
Procedure
SiBE04-624
Points
When the pipes are
disconnected, protect the
both openings of pipe side
and unit side from entering
of moisture.
Undo the 2 hooks on the
side with a flat screwdriver.
Removal Procedure