Troubleshooting
Troubleshooting
156
Be sure to turn off power switch before connect or disconnect connector,
Caution
or parts damage may be occurred.
Dust or drip of
water is on the streamer
unit.
NO
Does the
multi-monitor LED blink about
1 minute after air purifying
operation starts.
YES
Turn off the power supply
(Turn off the breaker).
Is the streamer unit
installed surely.
YES
Check the connector connection
(S52).
Is it normal?
YES
Is the limit switch normal?
YES
Check the harness.
Is it broken?
NO
YES
NO
NO
* Connect the connector again for
ensuring the connection.
NO
NO
YES
SiBE04-624
Clean the streamer unit.
Clean the streamer unit.
Install it surely.
Correct the connection.
Replace the limit switch.
Replace the harness.
Replace the streamer unit
PCB (A5P)
Note 1.
Be careful not to break the
electrode in cleaning.
Note 2.
Since the electrode part is
electrified in high voltage,
be sure to pull out the
power supply plug or turn
breaker off in cleaning the
electrode part. (Touching in
electrifying results in
electrical shock.)
(R6006)