Firmware/POST Error Codes

If you replace FRUs and the problem is still not corrected, go to "MAP 1540:
Minimum Configuration" on page 2-37.
If you replace FRUs and the problem is corrected, go to MAP 410: Repair Checkout
in the Diagnostic Information for Multiple Bus Systems.
Table 3-1 (Page 1 of 40). Firmware Error Codes.
Error Code
Description
203w0xyz
w=loop number
x=0 missing link
y=port number
z=c for interconnect z=b missing
link back z=E RIO de-configured
20A80xxx
Remote initial program load (RIPL)
error
20A80000
Insufficient information to boot
20A80001
Client IP address is already in use
by other network device
20A80002
Cannot get gateway IP address
20A80003
Cannot get server hardware address
20A80004
Bootp failed
20A80005
File transmission (TFTP) failed
20D00xxx
Unknown/Unrecognized device
20D0000F
Self-test failed on device, no
error/location code information avail-
able
20D00010
Self-test failed on device, cannot
locate package
20D00011
Cannot determine Machine Model
20E00xxx
Security
3-2
RS/6000 Enterprise Server Model H Series Installation and Service Guide
Action / Possible Failing FRU
Check Cables, then Remote I/O
Verify the IP address
Change the IP address
Refer to "Firmware Checkpoints" on
page 3-52 table using code E174
Refer to "Firmware Checkpoints" on
page 3-52 table using code E174
Refer to "Firmware Checkpoints" on
page 3-52 table using code E175
Check network connection, try again
Check the System Management Services
error log entry (described in "Step 1020-4"
on page 2-9) for this error code. The
location code (if present) in the error log
entry should identify the location of the
failing device.
Contact your service support represen-
tative for assistance.
The machine model is part of the System
Vital Product Data. Perform corrective
actions listed for errors 2BA00050 and
2BA00051.