Table 3-1 (Page 9 of 40). Firmware Error Codes.
Error Code
Description
25A80211
Setenv/$Setenv parameter error -
value contains a null character
25AA0xxx
EEPROM problems
25AA0000
Unable to unlock EEPROM
25AA0001
Read-Recv error
25AA0002
Read-Trans error
25AA0003
Write-enable error
25AA0004
Write-recv error
25AA0005
Write-disable error
25AA0006
Write-Trans error
25AA0007
Unable to lock EEPROM
25B00001
No memory modules detected in
either memory card 1 or 2
25Cyyxxx
Memory card problems
3-10
RS/6000 Enterprise Server Model H Series Installation and Service Guide
Action / Possible Failing FRU
Refer to Action under error code
25A80xxx.
EEPROM problem resolution:
1. Ensure that the EEPROM Security
jumper is in the correct position if
doing a privileged-access password
install.
2. Retry the operation.
3. If retries do not solve the problem,
replace the I/O board. (See notes on
3-1.)
Refer to Action under error code
25AA0xxx.
Refer to Action under error code
25AA0xxx.
Refer to Action under error code
25AA0xxx.
Refer to Action under error code
25AA0xxx.
Refer to Action under error code
25AA0xxx.
Refer to Action under error code
25AA0xxx.
Refer to Action under error code
25AA0xxx.
Refer to Action under error code
25AA0xxx.
1. Reseat any installed memory card(s)
and retry.
2. Reseat any installed memory modules
on the installed memory cards.
3. Replace memory card(s).
See "Memory PD Bits" on page 3-42 for
definition of "yy".
Use the location code obtained from the
SMS Error Log utility (described in MAP
Step 1020-4) to identify which memory
module (or memory module pair) the error
is reported against.